fix(firmware+frontend): remove binary_parser_reset() re-deploy wipes CRC + tighten INIT poll
Firmware (state_machine.c): - Remove binary_parser_reset() from SERIAL_BRIDGE→RECEIVING handler - Remove binary_parser_reset() from ERROR→RECEIVING handler - Parser's INIT handler already resets itself; calling reset AFTER INIT payload processing wipes expected_total_crc to 0 → CRC fail Frontend (ble-deployer.ts): - Tighten INIT readValue poll: state===1 (RECEIVING) only Previously accepted state >= 1 && <= 4 which could false-positive on FLASHING(3) or SERIAL_BRIDGE(4) stale states Cache v9 → v10
This commit is contained in:
parent
6ccbb88678
commit
1d3a48940e
|
|
@ -367,8 +367,11 @@ export class BLEHardwareDeployer {
|
|||
/* INIT: any non-IDLE(0), non-ERROR(5/6) state means command was processed.
|
||||
* DATA: state must stay RECEIVING(1) — error if >=5. */
|
||||
if (cmd === CMD_INIT) {
|
||||
if (state >= 1 && state <= 4) {
|
||||
console.log(`[BLE-CMD] ${cmdName}: state=${state} — INIT confirmed via read poll`);
|
||||
/* Only RECEIVING(1) means INIT was processed.
|
||||
* Don't accept FLASHING(3) or SERIAL_BRIDGE(4) —
|
||||
* those are stale states from a previous deploy. */
|
||||
if (state === 1) {
|
||||
console.log(`[BLE-CMD] ${cmdName}: state=1 (RECEIVING) — INIT confirmed via read poll`);
|
||||
return 'ok' as const;
|
||||
}
|
||||
} else { /* DATA */
|
||||
|
|
|
|||
|
|
@ -1,5 +1,5 @@
|
|||
// static/sw.js
|
||||
const CACHE_VERSION = 'elemes-v9';
|
||||
const CACHE_VERSION = 'elemes-v10';
|
||||
const STATIC_CACHE = `${CACHE_VERSION}-static`;
|
||||
const API_CACHE = `${CACHE_VERSION}-api`;
|
||||
const ASSET_CACHE = `${CACHE_VERSION}-assets`;
|
||||
|
|
|
|||
|
|
@ -168,7 +168,11 @@ void state_machine_process_event(sm_event_t event, void *data)
|
|||
case STATE_SERIAL_BRIDGE:
|
||||
if (event == EVENT_BLE_INIT) {
|
||||
serial_bridge_stop();
|
||||
binary_parser_reset();
|
||||
/* Don't call binary_parser_reset() here — the parser's INIT
|
||||
* handler (binary_parser.c:51-68) already resets buffer_offset,
|
||||
* buffer_size, memset, and state. Calling reset here wipes
|
||||
* expected_total_crc to 0 AFTER the parser already set it
|
||||
* from the INIT payload, causing END CRC verification to fail. */
|
||||
current_state = STATE_RECEIVING;
|
||||
led_set_pattern(LED_BLUE_BLINK);
|
||||
ESP_LOGI(TAG, "Transition: SERIAL_BRIDGE -> RECEIVING (re-deploy)");
|
||||
|
|
@ -185,7 +189,7 @@ void state_machine_process_event(sm_event_t event, void *data)
|
|||
if (event == EVENT_BLE_INIT) {
|
||||
ESP_LOGI(TAG, "Re-deploy from ERROR state — transition to RECEIVING");
|
||||
serial_bridge_stop();
|
||||
binary_parser_reset();
|
||||
/* Parser resets itself on INIT — see note in SERIAL_BRIDGE handler. */
|
||||
current_state = STATE_RECEIVING;
|
||||
led_set_pattern(LED_BLUE_BLINK);
|
||||
} else if (event == EVENT_BUTTON_RETRY) {
|
||||
|
|
|
|||